Sign In | Join Free | My qualitymp3player.com
qualitymp3player.com
Products
Search by Category
Home > Solid Surfaces >

TX-JS composite waterproof coating

Country/Region china
Company Hangzhou Tianxin Waterproof Material Co.,Ltd.
Categories Cement Waterproofer
Telephone 0571-88529808,88752848,88753713,400-600-5358
ICP License Issued by the Chinese Ministry
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    TX-JS composite waterproof coating

    Product Name:TX-JS composite waterproof coating
    Brief description :TianXin waterproof coating developed rapidly in recent years a new type of construction waterproof coating.
    Details:
    Polymer cement waterproof paint
    Main features:
    1 can be wet or dry surface of the base construction, and a strong adhesive.
    2 non-toxic, harmless, can be used for drinking water works.
    3. Construction safety, easy to operate unrestricted moisture content of the grass-roots level.
    4. Coating shells of high strength and high toughness, and good weatherability.
    Construction requirements:
    1 flexible waterproof coating for waterproof grade requirements can be applied to the roof, toilet and bathroom, basement waterproofing and other parts, in accordance with design requirements of different water levels can be used alone, can also be implemented together as a waterproof waterproof.
    2 flexible waterproof coating for the two-component, cement and bone powder from the composition, storage and custody should pay attention to moisture transport; liquid acrylic latex from the composition, without any pollution and the risk of fire, riot, storage and transport should pay attention to the custody of antifreeze (not less than 0 ℃)
    3 using two sets of points will be mixed in proportion and in full uniform mixing, a mixture of flexible waterproof coating for use in 1 hour after each use should be stirred to prevent precipitation aggregate.
    4 Flexible Waterproof Coatings generally not be less than the temperature 5 ℃, the dry film-forming process should avoid sun exposure or excessive heat to prevent water evaporation and erosion should be avoided, otherwise the quality of the impact of film.
    5 to be waterproof flexible film-forming curable dry film thickness is recommended for the surface water water conservation in order to make them full of cement hydration and improve strength and prevent cracks.
    The construction procedure
    Requirements and to deal with the grass-roots level:
    The surface of a grass-roots level should be a solid, smooth., from sand, cracks and surface phenomena such as cellular.
    2 grass-roots level and the cross-plane should be made part of the corner arc and so on.
    3 pre-construction clean up the grass-roots level to deal with the surface of any surface dust, floating sand, Ma, if the cellular surface, such as the formation of the phenomenon should be repaired after the construction.
    BAYDERM deal
    1 if the dense surface of the grass-roots level is not recommended waterproof polymer mortar (adhesive: water: cement: sand = 1:1:2:6) at the end of treatment, for the water diluted BAYDERM flexible waterproof coating, BAYDERM should fully dry before the next Road Construction.
    2 pre-construction drying, if the grass-roots level in particular (whether or not BAYDERM deal), it is recommended to be water wet the surface of water was sufficient to absorb the grass-roots non-floating construction after the next.
    Construction of waterproof coating
    1 flexible waterproof coating should be uniform all over the sub-layered coating, each coating shall not pay attention to the phenomenon of Tu, grass-roots connections and corners, such as the construction site should be the focus of attention can not be missed.
    2 Cross Road, the construction and coating operations, attention should be paid before the Road membrane dry film, and by the possible handling of conservation can be cured together after the paint coating, the thickness of each coating preferably does not exceed 0.5mm. (Generally a thickness of 1.2-1.5mm thick, the amount of 2-3KG / )
    3 levels high during the construction of the waterproof layer, the second time in brushing waterproof layer, to pave and stick non-woven polypropylene fiber filament, should be dealt with
    Additional Notes:
    1 sub-coating or cross-over construction, special attention should be completely dry before coating Road Master before the operation, has not been any damage cadres bit flexible waterproof coating are repaired promptly.
    2 in case of rain after construction should be covered by the protection of the surface coating material. High temperature water vapor evaporating too quickly, the recommended post-curing flexible waterproof coating the surface of one or two water conservation.
    3 configured to be flexible waterproof coating construction in the life of other (less than 1 hours) use, has been used with good paint, containers should be kept covered with waterproof gas evaporation, causing the surface crust. If the surface crust is used to remove crust and then use. Technical specifications of the construction only as a waterproof coating for the construction of a special reference, the construction changes that may occur in the construction should be the basis o
    Quality TX-JS composite waterproof coating for sale
    Send your message to this supplier
     
    From:
    Enter your email please.
    To: Hangzhou Tianxin Waterproof Material Co.,Ltd.
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2018 qualitymp3player.com. All rights reserved.